Goode Plumbing In Back Of The Yards, Chicago, IL | Goode Plumbing
24/7 Emergency Service
Count on us round-the-clock for immediate assistance, ensuring your plumbing concerns are addressed promptly and efficiently, day or night.
Lifetime Guarantee
We offer a Lifetime Warranty to guarantee against defects in our workmanship

Goode Plumbing in Back of the Yards, Chicago, IL

Goode Plumbing van

When plumbing issues strike in Back of the Yards, it doesn’t just disrupt your routine—it affects the comfort and safety of your home or the smooth operation of your business. At Goode Plumbing, we know this community well, and we understand that Back of the Yards families and businesses need a plumbing partner they can depend on. That’s why we’ve built our reputation on reliable solutions, honest service, and treating every customer like a neighbor.

From small leaks to major sewer repairs, our skilled team brings both technical expertise and neighborly care to every job. With quick response times, clear communication, and long-lasting solutions, we’re here to keep your property in excellent shape. Give our plumbers a call at (773) 280-7921 or contact us online to get scheduled. 

Plumbing Services Rooted in Back of the Yards

Back of the Yards is one of Chicago’s most historic neighborhoods. Known for resilience and strong community values, it’s a place where families and businesses take pride in their homes and buildings. Many of the properties here are older, with unique plumbing systems that need specialized attention. 

Goode Plumbing is proud to serve this area, offering expert plumbing solutions that are tailored for both vintage properties and modern construction. When you call us, you’re not just getting a plumber—you’re getting a trusted local partner who cares about your neighborhood.

Residential Plumbing for Back of the Yards Homes

Your home is more than four walls; it’s where your family gathers, rests, and builds memories. Plumbing issues can throw that comfort off balance. Our residential plumbing services in Back of the Yards are designed to restore peace of mind quickly, while treating your home with the care and respect it deserves.

Commercial Plumbing Services for Local Businesses

Plumbing problems don’t just inconvenience a business—they can cause costly downtime. Back of the Yards business owners trust Goode Plumbing because we respond quickly and deliver professional results that keep operations running smoothly.

  • Fixture Installation & Repair: We install and maintain high-quality fixtures that withstand heavy use in commercial settings.
  • Plumbing for Renovations & Build-Outs: From initial planning and permits to installation, we make sure your project is completed efficiently and up to code.
  • 24/7 Emergency Commercial Plumbing: Our team is ready around the clock to minimize downtime and prevent disruptions to your business.
  • Grease Trap Cleaning & Drain Maintenance: Essential for restaurants and food service businesses, our services keep your kitchen compliant and clog-free.

Emergency Plumbing Repairs in Back of the Yards

Some plumbing issues can’t wait. Burst pipes, flooded basements, and sewer backups can cause major damage if not addressed immediately. That’s why Goode Plumbing provides 24/7 emergency plumbing services across Back of the Yards.

We respond quickly, diagnose the issue, and provide clear, straightforward solutions that restore your peace of mind.

  • Frozen or burst pipes
  • Sudden basement flooding
  • Sewer line backups and blockages
  • Broken sump or ejector pumps
  • Water heater failures

Sewer and Drain Services for Chicago Homes

Drain and sewer issues don’t just cause frustration—they can lead to property damage and health hazards if ignored. Our sewer and drain services in Back of the Yards  are designed to fix problems quickly and thoroughly so you can get back to normal life.

Water Heater Services for Back of the Yards Residents

Residential Water Heater
Residential Water Heater with the panel removed for repairs or adjustments to the thermostat. Please also see my lightbox:

Hot water is essential to everyday life, from morning showers to running laundry. Goode Plumbing ensures your water heater is always ready when you need it most.

Why Back of the Yards Chooses Goode Plumbing

Choosing the right plumber is about trust. Back of the Yards residents and businesses continue to call us because:

  • We’re a local Chicago company with a focus on community values
  • Our plumbers are friendly, skilled, and respectful of your property
  • Pricing is transparent—no hidden fees or surprises
  • We respond quickly and offer 24/7 emergency support
  • Our workmanship and materials are built to last

Call Your Back of the Yards Plumbing Experts Today

Plumbing issues don’t wait—and neither should you. Whether you’re dealing with a stubborn clog, a leaky pipe, or planning a home upgrade, Goode Plumbing is ready to help. Call us today at (773) 280-7921 or schedule service online for dependable plumbing in Back of the Yards, Chicago.

Recent Jobs and Reviews in Chicago, IL

Chicago, IL at a glance

Goode Plumbing has completed 20 jobs in Chicago, IL in August 2026.

The most recent job was on August 24, 2026.

Goode Plumbing has completed 4,946 jobs in Chicago, IL in the last 12 months.

Job Locations and Reviews

Chicago, IL - Upgraded existing single-stage water filtration system to a two-stage configuration on copper manifold plumbing system. Integrated new filtration unit inline with existing copper piping, installed necessary shut-off valves, and ensured proper connections to maintain water distribution to all branch lines throughout the building.
Jacob N.
Jacob N. Checked in
Upgraded existing single-stage water filtration system to a two-stage configuration on copper manifold plumbing system. Integrated new filtration unit inline with existing copper piping, installed necessary shut-off valves, and ensured proper connections to maintain water distribution to all branch lines throughout the building.
Chicago, IL 60609
Conducted comprehensive plumbing assessment of century-old residential property to provide estimate for complete repiping of bathroom and additional areas. Evaluated existing lead and galvanized water supply lines throughout the structure, documenting deteriorated piping systems requiring replacement with copper piping to meet current code requirements. Inspected bathroom plumbing infrastructure including vertical pipe stacks experiencing active leak conditions. Assessed under-sink drainage system with PVC P-trap configuration and examined water heater installation with aged copper supply lines showing significant oxidation and patina. Documented existing plumbing conditions through photographic evidence including cabinet-mounted fixtures, supply line routing, and mechanical room infrastructure. Evaluated scope of work necessary to bring entire plumbing system into code compliance, focusing on bathroom stack replacement and transition from obsolete materials to modern copper distributi
Conducted comprehensive plumbing assessment of century-old residential property to provide estimate for complete repiping of bathroom and additional areas. Evaluated existing lead and galvanized water supply lines throughout the structure, documenting deteriorated piping systems requiring replacement with copper piping to meet current code requirements. Inspected bathroom plumbing infrastructure including vertical pipe stacks experiencing active leak conditions. Assessed under-sink drainage system with PVC P-trap configuration and examined water heater installation with aged copper supply lines showing significant oxidation and patina. Documented existing plumbing conditions through photographic evidence including cabinet-mounted fixtures, supply line routing, and mechanical room infrastructure. Evaluated scope of work necessary to bring entire plumbing system into code compliance, focusing on bathroom stack replacement and transition from obsolete materials to modern copper distributi
Jacob N.
Jacob N. Checked in
Conducted comprehensive plumbing assessment of century-old residential property to provide estimate for complete repiping of bathroom and additional areas. Evaluated existing lead and galvanized water supply lines throughout the structure, documenting deteriorated piping systems requiring replacement with copper piping to meet current code requirements. Inspected bathroom plumbing infrastructure including vertical pipe stacks experiencing active leak conditions. Assessed under-sink drainage system with PVC P-trap configuration and examined water heater installation with aged copper supply lines showing significant oxidation and patina. Documented existing plumbing conditions through photographic evidence including cabinet-mounted fixtures, supply line routing, and mechanical room infrastructure. Evaluated scope of work necessary to bring entire plumbing system into code compliance, focusing on bathroom stack replacement and transition from obsolete materials to modern copper distributi
Chicago, IL 60613
Conducted comprehensive plumbing assessment of basement area exhibiting severe water damage and deteriorated conditions. Evaluated multiple copper supply lines showing significant oxidation and corrosion running vertically along damaged walls. Documented extensive structural deterioration including peeling paint layers, exposed substrate, and moisture-related damage throughout the space. Identified aging plumbing infrastructure requiring repair or replacement and provided recommendations for remediation of affected piping systems and water-damaged surfaces.
Conducted comprehensive plumbing assessment of basement area exhibiting severe water damage and deteriorated conditions. Evaluated multiple copper supply lines showing significant oxidation and corrosion running vertically along damaged walls. Documented extensive structural deterioration including peeling paint layers, exposed substrate, and moisture-related damage throughout the space. Identified aging plumbing infrastructure requiring repair or replacement and provided recommendations for remediation of affected piping systems and water-damaged surfaces.
Danny M.
Danny M. Checked in
Conducted comprehensive plumbing assessment of basement area exhibiting severe water damage and deteriorated conditions. Evaluated multiple copper supply lines showing significant oxidation and corrosion running vertically along damaged walls. Documented extensive structural deterioration including peeling paint layers, exposed substrate, and moisture-related damage throughout the space. Identified aging plumbing infrastructure requiring repair or replacement and provided recommendations for remediation of affected piping systems and water-damaged surfaces.
Chicago, IL 60618
Performed maintenance service on AO Smith tankless water heater experiencing intermittent operation with error code display. Diagnosed faulty air fuel sensor causing unit to cycle on and off. Inspected internal control panel, electrical connections, and sensor assembly. Documented existing copper piping configuration, expansion tank, safety valves, and drip pan installation. Provided assessment that air fuel sensor requires replacement to restore proper unit operation and resolve error code condition.
Performed maintenance service on AO Smith tankless water heater experiencing intermittent operation with error code display. Diagnosed faulty air fuel sensor causing unit to cycle on and off. Inspected internal control panel, electrical connections, and sensor assembly. Documented existing copper piping configuration, expansion tank, safety valves, and drip pan installation. Provided assessment that air fuel sensor requires replacement to restore proper unit operation and resolve error code condition.
Chip R.
Chip R. Checked in
Performed maintenance service on AO Smith tankless water heater experiencing intermittent operation with error code display. Diagnosed faulty air fuel sensor causing unit to cycle on and off. Inspected internal control panel, electrical connections, and sensor assembly. Documented existing copper piping configuration, expansion tank, safety valves, and drip pan installation. Provided assessment that air fuel sensor requires replacement to restore proper unit operation and resolve error code condition.
Chicago, IL 60614
Conducted comprehensive plumbing assessment addressing three separate concerns: corroded piping near water meter shut-off valve requiring replacement, recurring sewer fly infestation necessitating verification of drain line clearance following previous scope inspections, and shower base leak requiring investigation. Documented existing conditions including deteriorated pipe insulation at shut-off location and concrete floor surface conditions for estimate preparation.
Conducted comprehensive plumbing assessment addressing three separate concerns: corroded piping near water meter shut-off valve requiring replacement, recurring sewer fly infestation necessitating verification of drain line clearance following previous scope inspections, and shower base leak requiring investigation. Documented existing conditions including deteriorated pipe insulation at shut-off location and concrete floor surface conditions for estimate preparation.
Jacob N.
Jacob N. Checked in
Conducted comprehensive plumbing assessment addressing three separate concerns: corroded piping near water meter shut-off valve requiring replacement, recurring sewer fly infestation necessitating verification of drain line clearance following previous scope inspections, and shower base leak requiring investigation. Documented existing conditions including deteriorated pipe insulation at shut-off location and concrete floor surface conditions for estimate preparation.
chicago, IL 60612
Chicago, IL - Responded to report of water leak from cracked shower basin penetrating to basement level at coach house property. Performed thorough inspection of shower fixture and underlying plumbing system, including examination of P-trap assembly, drainage connections, and surrounding wooden framework for water damage and structural integrity. Documented existing plumbing configuration with white PVC components and assessed extent of basin deterioration causing active leak. Provided recommendations for repair options to eliminate water intrusion and prevent further damage to lower level.
Isai M.
Isai M. Checked in
Responded to report of water leak from cracked shower basin penetrating to basement level at coach house property. Performed thorough inspection of shower fixture and underlying plumbing system, including examination of P-trap assembly, drainage connections, and surrounding wooden framework for water damage and structural integrity. Documented existing plumbing configuration with white PVC components and assessed extent of basin deterioration causing active leak. Provided recommendations for repair options to eliminate water intrusion and prevent further damage to lower level.
Chicago, IL 60657
Responded to service call for low water pressure at kitchen sink and toilet flushing issues. Inspected kitchen plumbing and identified reduced flow at sink faucet. Examined bathroom toilet tank and found faulty flapper valve assembly and flush valve mechanism causing inconsistent flushing and requiring manual chain operation to refill tank. Noted discolored water and mineral buildup in tank interior indicating potential supply line sediment issues. Documented toilet components including American Standard flush valve assembly with red cap, black overflow tube, and blue flapper valve connected by chain. Recommended flapper replacement and flush valve adjustment to restore proper automatic flushing function. Advised addressing water discoloration and sediment concerns to prevent future pressure issues throughout plumbing system.
Responded to service call for low water pressure at kitchen sink and toilet flushing issues. Inspected kitchen plumbing and identified reduced flow at sink faucet. Examined bathroom toilet tank and found faulty flapper valve assembly and flush valve mechanism causing inconsistent flushing and requiring manual chain operation to refill tank. Noted discolored water and mineral buildup in tank interior indicating potential supply line sediment issues. Documented toilet components including American Standard flush valve assembly with red cap, black overflow tube, and blue flapper valve connected by chain. Recommended flapper replacement and flush valve adjustment to restore proper automatic flushing function. Advised addressing water discoloration and sediment concerns to prevent future pressure issues throughout plumbing system.
Chris K.
Chris K. Checked in
Responded to service call for low water pressure at kitchen sink and toilet flushing issues. Inspected kitchen plumbing and identified reduced flow at sink faucet. Examined bathroom toilet tank and found faulty flapper valve assembly and flush valve mechanism causing inconsistent flushing and requiring manual chain operation to refill tank. Noted discolored water and mineral buildup in tank interior indicating potential supply line sediment issues. Documented toilet components including American Standard flush valve assembly with red cap, black overflow tube, and blue flapper valve connected by chain. Recommended flapper replacement and flush valve adjustment to restore proper automatic flushing function. Advised addressing water discoloration and sediment concerns to prevent future pressure issues throughout plumbing system.
Chicago, IL 60660
Chicago, IL - Responded to shower and tub enclosure water intrusion issue in 25-year-old residential bathroom. Identified failed caulking and sealant at shower pan perimeter allowing water penetration into adjacent drywall, along with leaking showerhead connection. Removed deteriorated sealant, dried affected areas, and applied fresh silicone caulking to all shower-to-wall joints and floor transitions. Tightened and resealed showerhead assembly with plumber's tape to eliminate fixture leak. Verified proper water containment and advised monitoring for any signs of continued moisture issues.
Lowden S.
Lowden S. Checked in
Responded to shower and tub enclosure water intrusion issue in 25-year-old residential bathroom. Identified failed caulking and sealant at shower pan perimeter allowing water penetration into adjacent drywall, along with leaking showerhead connection. Removed deteriorated sealant, dried affected areas, and applied fresh silicone caulking to all shower-to-wall joints and floor transitions. Tightened and resealed showerhead assembly with plumber's tape to eliminate fixture leak. Verified proper water containment and advised monitoring for any signs of continued moisture issues.
Chicago, IL 60657
Responded to no hot water complaint and assessed failed tank water heater originally installed in 2021. Documented existing State brand water heater installation with measurements and photographed current condition of unit, including all connections, piping configuration, and mechanical room layout for estimate preparation.
Responded to no hot water complaint and assessed failed tank water heater originally installed in 2021. Documented existing State brand water heater installation with measurements and photographed current condition of unit, including all connections, piping configuration, and mechanical room layout for estimate preparation.
Jacob N.
Jacob N. Checked in
Responded to no hot water complaint and assessed failed tank water heater originally installed in 2021. Documented existing State brand water heater installation with measurements and photographed current condition of unit, including all connections, piping configuration, and mechanical room layout for estimate preparation.
Chicago, IL 60612
Chicago, IL - Responded to service call for malfunctioning main water shutoff valve located above the tanked water heater unit. Inspected the valve assembly and plumbing connections in the mechanical closet, identifying the non-operational shutoff valve with blue wheel handle positioned on the cold water supply line. Evaluated the complete water heater installation including copper piping, galvanized exhaust venting, and associated shutoff valves to assess system functionality and safety.
Lowden S.
Lowden S. Checked in
Responded to service call for malfunctioning main water shutoff valve located above the tanked water heater unit. Inspected the valve assembly and plumbing connections in the mechanical closet, identifying the non-operational shutoff valve with blue wheel handle positioned on the cold water supply line. Evaluated the complete water heater installation including copper piping, galvanized exhaust venting, and associated shutoff valves to assess system functionality and safety.
Chicago, IL 60647
Responded to water leak call at century-old residential property. Upon arrival, conducted thorough inspection of plumbing infrastructure in basement mechanical room. Located active leak at main water meter assembly, where aged corrugated piping connections showed signs of deterioration and compromised seals. 

Assessed secondary plumbing fixtures in bathroom area, identifying additional concerns with vintage brass valve assemblies featuring blue-handled shutoffs. Observed significant mineral deposits, corrosion, and water staining around drain opening and mounting surfaces, indicating chronic moisture exposure consistent with slow leak conditions over extended period.

Performed emergency repairs to water meter connections, replacing deteriorated gaskets and tightening compression fittings to restore watertight seal. Tested system under full pressure to verify leak elimination. Documented existing conditions of aged brass fixtures and recommended monitoring for future service needs due
Responded to water leak call at century-old residential property. Upon arrival, conducted thorough inspection of plumbing infrastructure in basement mechanical room. Located active leak at main water meter assembly, where aged corrugated piping connections showed signs of deterioration and compromised seals. 

Assessed secondary plumbing fixtures in bathroom area, identifying additional concerns with vintage brass valve assemblies featuring blue-handled shutoffs. Observed significant mineral deposits, corrosion, and water staining around drain opening and mounting surfaces, indicating chronic moisture exposure consistent with slow leak conditions over extended period.

Performed emergency repairs to water meter connections, replacing deteriorated gaskets and tightening compression fittings to restore watertight seal. Tested system under full pressure to verify leak elimination. Documented existing conditions of aged brass fixtures and recommended monitoring for future service needs due
Chris K.
Chris K. Checked in
Responded to water leak call at century-old residential property. Upon arrival, conducted thorough inspection of plumbing infrastructure in basement mechanical room. Located active leak at main water meter assembly, where aged corrugated piping connections showed signs of deterioration and compromised seals. Assessed secondary plumbing fixtures in bathroom area, identifying additional concerns with vintage brass valve assemblies featuring blue-handled shutoffs. Observed significant mineral deposits, corrosion, and water staining around drain opening and mounting surfaces, indicating chronic moisture exposure consistent with slow leak conditions over extended period. Performed emergency repairs to water meter connections, replacing deteriorated gaskets and tightening compression fittings to restore watertight seal. Tested system under full pressure to verify leak elimination. Documented existing conditions of aged brass fixtures and recommended monitoring for future service needs due
Chicago, IL 60625
Responded to no hot water complaint at residential property. Upon arrival, inspected Performance brand tanked water heater located in basement utility area. Verified complete loss of hot water throughout home. Conducted diagnostic assessment of water heater unit, examining control assembly, thermostat operation, and heating elements. Evaluated electrical connections and power supply to unit. Inspected emergency shutdown system and safety controls on equipment. Checked gas supply lines, valves, and connections for proper operation. Assessed overall condition of water heater including tank integrity, temperature and pressure relief valve, and venting system. Examined surrounding plumbing infrastructure including copper supply lines and associated piping. Documented equipment specifications and current operating conditions. Photographed installation for service records showing water heater configuration, piping layout, and mechanical systems. Identified error condition preventing proper h
Responded to no hot water complaint at residential property. Upon arrival, inspected Performance brand tanked water heater located in basement utility area. Verified complete loss of hot water throughout home. Conducted diagnostic assessment of water heater unit, examining control assembly, thermostat operation, and heating elements. Evaluated electrical connections and power supply to unit. Inspected emergency shutdown system and safety controls on equipment. Checked gas supply lines, valves, and connections for proper operation. Assessed overall condition of water heater including tank integrity, temperature and pressure relief valve, and venting system. Examined surrounding plumbing infrastructure including copper supply lines and associated piping. Documented equipment specifications and current operating conditions. Photographed installation for service records showing water heater configuration, piping layout, and mechanical systems. Identified error condition preventing proper h
Nick D.
Nick D. Checked in
Responded to no hot water complaint at residential property. Upon arrival, inspected Performance brand tanked water heater located in basement utility area. Verified complete loss of hot water throughout home. Conducted diagnostic assessment of water heater unit, examining control assembly, thermostat operation, and heating elements. Evaluated electrical connections and power supply to unit. Inspected emergency shutdown system and safety controls on equipment. Checked gas supply lines, valves, and connections for proper operation. Assessed overall condition of water heater including tank integrity, temperature and pressure relief valve, and venting system. Examined surrounding plumbing infrastructure including copper supply lines and associated piping. Documented equipment specifications and current operating conditions. Photographed installation for service records showing water heater configuration, piping layout, and mechanical systems. Identified error condition preventing proper h
Chicago, IL 60618
Successfully relocated a tanked water heater installation from its original position to the opposite wall within the utility area. The project involved disconnecting and repositioning an A.O. Smith tank water heater, including the recirculation pump system mounted on top of the unit. All supply and return plumbing connections were reconfigured, including copper water lines and PVC venting, with proper fittings and support brackets installed to meet code requirements. Electrical connections were relocated and secured, ensuring proper power supply to both the water heater and recirculation pump. The installation was completed with all components properly mounted, connections tested for leaks, and the system restored to full operational status.
Successfully relocated a tanked water heater installation from its original position to the opposite wall within the utility area. The project involved disconnecting and repositioning an A.O. Smith tank water heater, including the recirculation pump system mounted on top of the unit. All supply and return plumbing connections were reconfigured, including copper water lines and PVC venting, with proper fittings and support brackets installed to meet code requirements. Electrical connections were relocated and secured, ensuring proper power supply to both the water heater and recirculation pump. The installation was completed with all components properly mounted, connections tested for leaks, and the system restored to full operational status.
Chris K.
Chris K. Checked in
Successfully relocated a tanked water heater installation from its original position to the opposite wall within the utility area. The project involved disconnecting and repositioning an A.O. Smith tank water heater, including the recirculation pump system mounted on top of the unit. All supply and return plumbing connections were reconfigured, including copper water lines and PVC venting, with proper fittings and support brackets installed to meet code requirements. Electrical connections were relocated and secured, ensuring proper power supply to both the water heater and recirculation pump. The installation was completed with all components properly mounted, connections tested for leaks, and the system restored to full operational status.
Chicago, IL 60618
Responded to leak originating from ceiling in unit below. Upon inspection of mechanical room and HVAC equipment area, assessed copper piping, water heater connections, and drainage systems for source of water intrusion. Documented existing plumbing infrastructure including copper supply lines, PVC drainage piping, and water heater installation to identify leak pathway and coordinate repairs with affected units.
Responded to leak originating from ceiling in unit below. Upon inspection of mechanical room and HVAC equipment area, assessed copper piping, water heater connections, and drainage systems for source of water intrusion. Documented existing plumbing infrastructure including copper supply lines, PVC drainage piping, and water heater installation to identify leak pathway and coordinate repairs with affected units.
Nick D.
Nick D. Checked in
Responded to leak originating from ceiling in unit below. Upon inspection of mechanical room and HVAC equipment area, assessed copper piping, water heater connections, and drainage systems for source of water intrusion. Documented existing plumbing infrastructure including copper supply lines, PVC drainage piping, and water heater installation to identify leak pathway and coordinate repairs with affected units.
Chicago, IL 60657
Responded to toilet leak investigation in century-old residential property. Upon inspection, identified improper sealing around toilet flange where PVC drain pipe penetrates subfloor. Previous foam sealant installation showed signs of deterioration and inadequate moisture barrier, contributing to leak conditions. Documented existing conditions including exposed multi-layer flooring around drain penetration and compromised foam insulation with visible staining indicating water intrusion. Assessed bathroom ceiling and ventilation system to determine extent of potential moisture damage from leak. Provided photographic documentation of flange area and overhead conditions for repair recommendations.
Responded to toilet leak investigation in century-old residential property. Upon inspection, identified improper sealing around toilet flange where PVC drain pipe penetrates subfloor. Previous foam sealant installation showed signs of deterioration and inadequate moisture barrier, contributing to leak conditions. Documented existing conditions including exposed multi-layer flooring around drain penetration and compromised foam insulation with visible staining indicating water intrusion. Assessed bathroom ceiling and ventilation system to determine extent of potential moisture damage from leak. Provided photographic documentation of flange area and overhead conditions for repair recommendations.
Chris K.
Chris K. Checked in
Responded to toilet leak investigation in century-old residential property. Upon inspection, identified improper sealing around toilet flange where PVC drain pipe penetrates subfloor. Previous foam sealant installation showed signs of deterioration and inadequate moisture barrier, contributing to leak conditions. Documented existing conditions including exposed multi-layer flooring around drain penetration and compromised foam insulation with visible staining indicating water intrusion. Assessed bathroom ceiling and ventilation system to determine extent of potential moisture damage from leak. Provided photographic documentation of flange area and overhead conditions for repair recommendations.
Chicago, IL 60647
Completed plumbing estimate for sump pump area with deteriorated drainage and supply lines. Documented existing conditions including severely corroded cast iron vertical drain pipe with failing connections, oxidized copper supply lines with verdigris buildup at joints, and mixed PVC/copper configuration requiring assessment. The inspection revealed aging plumbing infrastructure with compromised pipe integrity, corroded fittings, and potential leak points at connection interfaces that will need replacement to ensure proper sump pump operation and prevent water damage.
Completed plumbing estimate for sump pump area with deteriorated drainage and supply lines. Documented existing conditions including severely corroded cast iron vertical drain pipe with failing connections, oxidized copper supply lines with verdigris buildup at joints, and mixed PVC/copper configuration requiring assessment. The inspection revealed aging plumbing infrastructure with compromised pipe integrity, corroded fittings, and potential leak points at connection interfaces that will need replacement to ensure proper sump pump operation and prevent water damage.
Lowden S.
Lowden S. Checked in
Completed plumbing estimate for sump pump area with deteriorated drainage and supply lines. Documented existing conditions including severely corroded cast iron vertical drain pipe with failing connections, oxidized copper supply lines with verdigris buildup at joints, and mixed PVC/copper configuration requiring assessment. The inspection revealed aging plumbing infrastructure with compromised pipe integrity, corroded fittings, and potential leak points at connection interfaces that will need replacement to ensure proper sump pump operation and prevent water damage.
Chicago, IL 60656
Completed comprehensive plumbing repair addressing multiple critical water system failures in a multi-unit building. Utilized pipe freezing technology to isolate and replace a leaking 1" galvanized main shut-off valve without disrupting water service to eight adjacent units. Cut into the existing galvanized line, removed the failed valve, and installed a new 1" IP ball valve with approximately 3 feet of new pipework. Thawed the line and verified proper operation under full pressure.

Replaced a failed hose bib shut-off valve and exterior spigot assembly. Shut down the building's water supply, drained the system, and cut into the deteriorated 3/4" galvanized line. Removed the defective valve with broken handle and the leaking hose bib. Installed a new 3/4" shut-off valve and exterior spigot, restored water pressure, and tested all connections for leaks and proper functionality.

All work performed on aging galvanized water lines showing significant corrosion and deterioration. System pr
Completed comprehensive plumbing repair addressing multiple critical water system failures in a multi-unit building. Utilized pipe freezing technology to isolate and replace a leaking 1" galvanized main shut-off valve without disrupting water service to eight adjacent units. Cut into the existing galvanized line, removed the failed valve, and installed a new 1" IP ball valve with approximately 3 feet of new pipework. Thawed the line and verified proper operation under full pressure.

Replaced a failed hose bib shut-off valve and exterior spigot assembly. Shut down the building's water supply, drained the system, and cut into the deteriorated 3/4" galvanized line. Removed the defective valve with broken handle and the leaking hose bib. Installed a new 3/4" shut-off valve and exterior spigot, restored water pressure, and tested all connections for leaks and proper functionality.

All work performed on aging galvanized water lines showing significant corrosion and deterioration. System pr
Chris K.
Chris K. Checked in
Completed comprehensive plumbing repair addressing multiple critical water system failures in a multi-unit building. Utilized pipe freezing technology to isolate and replace a leaking 1" galvanized main shut-off valve without disrupting water service to eight adjacent units. Cut into the existing galvanized line, removed the failed valve, and installed a new 1" IP ball valve with approximately 3 feet of new pipework. Thawed the line and verified proper operation under full pressure. Replaced a failed hose bib shut-off valve and exterior spigot assembly. Shut down the building's water supply, drained the system, and cut into the deteriorated 3/4" galvanized line. Removed the defective valve with broken handle and the leaking hose bib. Installed a new 3/4" shut-off valve and exterior spigot, restored water pressure, and tested all connections for leaks and proper functionality. All work performed on aging galvanized water lines showing significant corrosion and deterioration. System pr
Chicago, IL 60625
Responded to slow-draining shower in bathroom and assessed drain condition as requested. Upon inspection, identified hair and soap buildup causing partial blockage in the drain assembly. Cleared obstruction using appropriate drain cleaning tools and verified proper water flow. Examined the brass drain fitting and overflow assembly—both components found to be in serviceable condition with no signs of corrosion or structural damage requiring replacement. Tested drainage multiple times to confirm complete resolution and advised on preventive maintenance practices.
Responded to slow-draining shower in bathroom and assessed drain condition as requested. Upon inspection, identified hair and soap buildup causing partial blockage in the drain assembly. Cleared obstruction using appropriate drain cleaning tools and verified proper water flow. Examined the brass drain fitting and overflow assembly—both components found to be in serviceable condition with no signs of corrosion or structural damage requiring replacement. Tested drainage multiple times to confirm complete resolution and advised on preventive maintenance practices.
Brian R.
Brian R. Checked in
Responded to slow-draining shower in bathroom and assessed drain condition as requested. Upon inspection, identified hair and soap buildup causing partial blockage in the drain assembly. Cleared obstruction using appropriate drain cleaning tools and verified proper water flow. Examined the brass drain fitting and overflow assembly—both components found to be in serviceable condition with no signs of corrosion or structural damage requiring replacement. Tested drainage multiple times to confirm complete resolution and advised on preventive maintenance practices.
Chicago, IL 60657
Responded to a multi-unit building for clogged toilet with water infiltration to unit below. Pulled and reset two toilets with replacement of failed wax rings and installation of new cast iron closet flanges. Performed main line rodding with Spartan equipment to clear blockage, followed by camera inspection to verify clearance and locate any additional issues in the drainage system.
Responded to a multi-unit building for clogged toilet with water infiltration to unit below. Pulled and reset two toilets with replacement of failed wax rings and installation of new cast iron closet flanges. Performed main line rodding with Spartan equipment to clear blockage, followed by camera inspection to verify clearance and locate any additional issues in the drainage system.
Brian R.
Brian R. Checked in
Responded to a multi-unit building for clogged toilet with water infiltration to unit below. Pulled and reset two toilets with replacement of failed wax rings and installation of new cast iron closet flanges. Performed main line rodding with Spartan equipment to clear blockage, followed by camera inspection to verify clearance and locate any additional issues in the drainage system.
Chicago, IL 60642
Responded to service call for main line leak repair in residential property. Upon inspection, identified moisture damage and staining on basement concrete floor indicating active leak in main sewer line. Assessed existing plumbing infrastructure including PVC drainage system, aged copper supply lines, and galvanized components showing signs of deterioration. Performed necessary main line repairs to resolve leak issue and restore proper drainage function. Additionally, installed customer-supplied shut off valve on toilet supply line, connecting flexible braided supply line from chrome angle stop valve to toilet tank with proper compression fittings to ensure leak-free operation. Tested all repairs for proper function and verified no active leaks present upon completion.
Responded to service call for main line leak repair in residential property. Upon inspection, identified moisture damage and staining on basement concrete floor indicating active leak in main sewer line. Assessed existing plumbing infrastructure including PVC drainage system, aged copper supply lines, and galvanized components showing signs of deterioration. Performed necessary main line repairs to resolve leak issue and restore proper drainage function. Additionally, installed customer-supplied shut off valve on toilet supply line, connecting flexible braided supply line from chrome angle stop valve to toilet tank with proper compression fittings to ensure leak-free operation. Tested all repairs for proper function and verified no active leaks present upon completion.
Jon H.
Jon H. Checked in
Responded to service call for main line leak repair in residential property. Upon inspection, identified moisture damage and staining on basement concrete floor indicating active leak in main sewer line. Assessed existing plumbing infrastructure including PVC drainage system, aged copper supply lines, and galvanized components showing signs of deterioration. Performed necessary main line repairs to resolve leak issue and restore proper drainage function. Additionally, installed customer-supplied shut off valve on toilet supply line, connecting flexible braided supply line from chrome angle stop valve to toilet tank with proper compression fittings to ensure leak-free operation. Tested all repairs for proper function and verified no active leaks present upon completion.
Chicago, IL 60625

 

What To Expect

Discover The Goode Plumbing Difference

24/7 Emergency Services

Count on us round-the-clock for immediate assistance, ensuring your plumbing concerns are addressed promptly and efficiently, day or night.

Over 300 Years Of Combined Experience

Our seasoned professionals bring knowledge and skill to every plumbing project, backed by centuries of collective experience.

Best Warranty in the Business

Our warranty coverage provides comprehensive protection, offers peace of mind and long-term assurance for your plumbing needs.

100% Satisfaction Guaranteed

We stand behind our workmanship and services, ensuring that you're completely satisfied with the results of our plumbing solutions.

Fully Licensed & Insured

We are fully licensed and insured, meeting all regulatory standards and providing added protection for your property and peace of mind.

One Stop Source

We provide all your plumbing needs under a single roof, saving you time and effort while ensuring top-notch quality and convenience.

24/7 Emergency Services

Count on us round-the-clock for immediate assistance, ensuring your plumbing concerns are addressed promptly and efficiently, day or night.

Over 300 Years Of Combined Experience

Our seasoned professionals bring knowledge and skill to every plumbing project, backed by centuries of collective experience.

Best Warranty in the Business

Our warranty coverage provides comprehensive protection, offers peace of mind and long-term assurance for your plumbing needs.

100% Satisfaction Guaranteed

We stand behind our workmanship and services, ensuring that you're completely satisfied with the results of our plumbing solutions.

Fully Licensed & Insured

We are fully licensed and insured, meeting all regulatory standards and providing added protection for your property and peace of mind.

One Stop Source

We provide all your plumbing needs under a single roof, saving you time and effort while ensuring top-notch quality and convenience.

Our Reviews

See What Our Clients Say.

We had a great experience with the plumbers at Goode Plumbing concerning a toilet issue. Adan was the one to diagnose as well as fix the issue. He kept us informed on what the issue was, the fix and the cost. He also cleaned up the areas that he had worked in. Thank you for your…

Nate H.

Nate H.

Chip and Ashton helped me pull off a spectacular Valentine’s Day surprise for my husband. After years of complaining about the lack of flushing power on our old home’s toilets Chip helped me select new ones that would complement our other bathroom fixtures and resolve my husband’s flushing woes. He scheduled the work for me (on…

Elyse K.

,

Elyse K.

,

The city turned off the water for several hours and once it was turned back on, debris from the pipes interfered with the water flow. In one of my toilets, the tank wasn’t refilling at all. Danny from Goode Plumbing did an excellent (and very fast) job in replacing the part. The toilet now works better…

James B.

,

James B.

,

I have been a Goode Plumbing customer for close to 20 years. They are always extremely professional and efficient. I highly recommend them for simple or complex jobs.

Christine T.

,

Christine T.

,

Jose and Danny came in for a smaller job and ended up helping me out with some other outstanding issues that needed to be addressed and it turned into a 2 day job. Jose talked me through everything and did not try to upsell. Instead, he offered realistic options. Professional and quality work – all around…

Jimmy S.

,

Jimmy S.

,